Different types of these assemblies may be specified according to the type of element required to pass through the feedthrough. Series WF assemblies cater for up to 12 bare or insulated wires – sizes from 24AWG (0.2mm2) to 8AWG (approx. 8.8mm2).
Insulators within WF feedthrough assemblies protect bare wires and provide additional isolation for Kapton® insulated power wires. These are rated max. 55A @ 600Vdc/850Vac max. Feedthroughs with power wires can be supplied as complete assemblies, ready for installation, with wires cut to specified lengths.
WF feedthroughs can also accommodate up to 12, small diameter sensor elements that must be electrically isolated from each other.
Seal on bare wires carrying instrumentation voltages – type WFR
Seal on small diameter sheathed sensors, max. 3.2mm dia. – type WFP
Pressure range: Vacuum to 700 bar*
Temperature range: <-200°C to +870°C*
316L Body (and seat where applicable). Follower and cap in 303 or 304
Choice of sealant materials
Individual wires can be replaced without complete disassembly
Reusable fitting – sealant and internal components replaceable
* dependent on sealant and fitting selected
![]() |
![]() |
||||
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
||||
![]() |
|||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |